First Steps

Thank you for purchasing the MX Series Essential safe. Let’s get your safe ready for programming with a few simple steps.

Master Code Programming

Change the default code as soon as possible to prevent unauthorized access.

Register your safe. Registration provides many benefits three year warranty, technical support, and ordering replacement keys should you misplace them. Visit https://vaulteksafe.com/support/vaultek-product-registration/ and enter the required information in the form and click submit.

Frequently Asked Questions

How to program the master code?

First time users should change the default code as soon as possible to prevent unauthorized access.

Programming Tips and Requirements

  • Your code can be as short as 4 digits, or up to 8 digits in length. We recommend a code 6 to 8 digits in length using at least one of each key to make it more difficult for someone to guess.
  • Avoid easy-to-guess digits such as 1234, 1111, 2222, etc.
  • Two keys cannot be pressed simultaneously.
  • The default master code is 1-2-3-4.
  • Programming a new master code will overwrite your previous code.

1. Open the safe. With the safe open, press and hold the ‘1’ key then the Program button together for 3 seconds until the LCD screen prompts you to enter your new code.

2. Enter your NEW master code.

3. Press and hold the ‘1’ key then the Program button together a second time for 3 seconds until the LCD screen prompts you to re-enter your new code.

4. Enter your NEW master code a second time.

5. Press and hold the ‘1’ key then the Program button together a third time for 3 seconds until the LCD screen confirms the code change is complete.

Troubleshooting! If you make a mistake and the new code will not work, simply start over with step 1.

How long do the batteries last?

This safes is powered by four AAA batteries that need to be installed. The batteries will run and last about 1 year. The included backup keys can be used at any time.

Can I use rechargeable batteries in my safe?

Yes, you can use rechargeable batteries. However, they will not recharge in the safe. You will need to remove them and charge them separately. For optimal performance, we recommend Duracell/Energizer or other reputable brands.

Does my safe need to be left plugged in?

No, you can plug in the safe as needed.

In the event you lose the keys and the battery dies, plug-in the safe to a power source.

How to disable the alarm?

Your safe features two alarms—Unauthorized Access Alert and Open Door Alarm—both of which are enabled by default.

Alert of Unauthorized Access: Your safe features an open door alarm that will sound when the safe door is left open for more than 8 minutes. To toggle this feature press and hold the ‘5’ key and Program button together for 3 seconds. The LCD screen will indicate OFF or ON.

Open Door Alarm: Your safe has a built-in accelerometer and corresponding alarm that alerts of any attacking to your safe including bumps and impacts, DMT (Impact Detection). There are four different DMT sensitivity settings; Low, Medium, High, and Disabled. You can toggle through these settings by pressing and holding the ‘7’ key and Program button together for 3 seconds. The screen will indicate the sensitivity.

Specs

The Vaultek® Essential MX safe model MX2e is a tough and rugged, quick access safe. Its solid structure and penetration resistant design makes it ideal for storing valuables such as firearms, jewelry, cash, and other personal items. Powered by four AAA batteries, the safe combines high security with complete access control.

Construction

Essential MX safes are built from rugged 14-gauge steel, offering durable protection. It features dual anti-impact latches that keeps the safe securely locked, even under force or impact, ensuring your valuables remain in place. The included mounting screws can secure the safe in place to the floor or wall.

Power

This safes is powered by four AAA batteries that need to be installed. The batteries will run and last about 1 year. The included backup keys can be used at any time.

Access Points

Essential MX offers rapid access via Smart Sense™ Keypad and Backup Manual Keys (two included).

Smart Sense™ Keypad: The master code can be 4 to 8 digits in length.

Backup Keys: Two keys are supplied. They are used to open the safe and will be needed to perform important functions such as factory reset.

Pre-Drilled Holes

Essential MX can be secured using the included mounting screws to a flat surface, such as wall or floor, using the pre-drilled holes.

Important! The safe must be securely mounted on the wall or floor to prevent the safe from falling.

Tip! You can use your own hardware specific to your application.

Battery Status

To check the battery level press and hold keys ‘6’ and ‘8’ together for 3 seconds. The LCD screen will indicate the battery level.

Security Sleep Mode

Activates when six (6) consecutive incorrect keypad entries are entered. The safe will not accept any entries for four minutes. If any additional attempts are made the alarm will beep. The security sleep mode can be cleared upon unlock of the safe by the backup keys.

Tamper Detection

To check for tampering press and hold keys ‘2’ and ‘4’ together for 3 seconds. The screen will indicate TAMPER OCCURRED or CLEAR. You can reset the tamper detection by opening the safe through one of the authorized entry points.

Sound (Medium by Default)

Your safe has four different sound pitches, Low, Medium, High, and OFF. To toggle the sound press and hold keys ‘1’ and ‘3’ together for 3 seconds. The screen will indicate the setting.

LCD Screen Brightness (75% by Default)

Your safe has four different brightness settings: 25%, 50%, 75%, and 100%. To toggle the brightness press and hold keys ‘3’ and ‘6’ together. The LCD screen will indicate the setting.

Interior Light and Duration (10s by Default)

Your safe has an interior light which can be toggled ON/OFF and has different interior light durations: 10 seconds, 30s, and 60s. To toggle the duration press and hold keys ‘3’ and ‘5’ together. The light will always stay ON when the safe is plugged into a power source.

Impact Detection (DMT) (Medium by Default)

Your safe has a built-in accelerometer and corresponding alarm that alerts of any attacking to your safe including bumps and impacts, DMT (Impact Detection). There are four different DMT sensitivity settings; Low, Medium, High, and Disabled. You can toggle through these settings by pressing and holding the ‘7’ key and Program button together for 3 seconds. The screen will indicate the sensitivity.

Alert of Unauthorized Access (ON by Default)

If enabled, and someone forcefully enters the safe or opens the safe by picking the lock, the keypad will start flashing and beeping. You can clear the alert by entering master code. To toggle this feature press and hold the ‘6’ key and Program button together for 3 seconds. The LCD screen will indicate ENABLED or DISABLED.

Open Door Alarm (ON by Default)

Your safe features an open door alarm that will sound when the safe door is left open for more than 8 minutes. To toggle this feature press and hold the ‘5’ key and Program button together for 3 seconds. The LCD screen will indicate OFF or ON.

Factory Reset

Open the safe using the included key and leave the key turned all the way in the clockwise position. Press and hold keys ‘2’ ‘7’ and the Program button together until the safe restarts. The factory reset will erase all programmed information and restores the safe to its factory default settings. The master code is rest to 1-2-3-4, and the safe will restart.